ACEY-GB1000 glove box is a high-performance, high-quality closed cycle working system that automatically absorbs water and oxygen molecules and purifies the working environment.
Build-in Purify System Vacuum Glove Box For Lithium Battery R&D Research
Description
ACEY-GB1000 glove box is a high-performance, high-quality closed cycle working system that automatically absorbs water and oxygen molecules and purifies the working environment. It provides an inert atmosphere of 1ppm O2 and H2O that can meet your specific cleaning requirements. This system is an economical circulating purification system designed to meet customer research and development.
The ACEY-GB1000 system includes a closed box, a transition chamber, a rotary vane vacuum pump and a circulating purification system integrated with a microcontroller operation panel. The inert gas purification system equipped with the standard Lab2000 system is equipped with a set of purification columns (fully automatic and renewable) to purify and maintain the atmosphere in the glove box.
Specification
Box body glove box
description
Material: stainless steel 1.4301 (SUS type 304), thickness 3 mm
Size: 1200mm(L) x 750mm(W) x 900mm(H)
volume
0.8 m³
Front window
Panel: 8 mm thick safety tempered glass or 10 mm thick polycarbonate (optional)
Size: 1123mm(L) x 839mm(H)
Glove mouth
Hard aluminum alloy material or polyoxymethylene material (optional)
220 mm diameter, O-ring seal
gloves
Material: Butyl rubber
Thickness: 0.4 mm or 0.8mm (optional)
filter
Outlet and inlet filters, filtration <0.3μm
illumination
LED lighting is located on the top of the front window
Leak rate
Leak detection is carried out in accordance with the oxygen method and
pressure change method in ISO 10648-2: 1994 / EJ/T 1096-1999 "Sealed Chamber-Part
2: Tightness Classification and Related Inspection Methods". The final
acceptance test is carried out in accordance with the standard of first-level
tightness <0.05 vol%/h.
GP20 gas purification system
description
Automatic removal of H2O and O2
Single purification column system, automatic regeneration (optional
GP200 double purification column)
Closed gas circulation pipeline
Use voltage
AC 230 V / 50-60 Hz, 10 A or AC 115 V / 50-60 Hz, 20 A (optional)
Working gas
Working gas: N2, Ar, He (purity ≥99.999%)
Regeneration gas: H2 accounts for 5%-10%, the rest is working gas
(purity ≥99.999%)
Vacuum pump
Specifications: Rotary vane vacuum pump, equipped with oil mist filter,
with gas ballast control
Flow rate: 12 m³/h (7 cfm), double substrate,
vacuum degree <2 x 10-3 mbar or dry pump (optional)
Cyclic unit
Oil-free high-speed fan
Air volume: 80 m³/h
valve
KF40 High Vacuum Valve
Leak rate
Leak detection is carried out in accordance with the oxygen method and
pressure change method in ISO 10648-2: 1994 / EJ/T 1096-1999 "Sealed
Chamber-Part 2: Tightness Classification and Related Inspection
Methods". The final acceptance test is carried out according to the
standard of level 1 tightness <0.05 vol%/h.
Control cabinet size
600mm (L) x 800mm (D) x 870mm (H)
Transition cabin
Large transition cabin
material
Stainless steel type 304 (1.4301),
thickness 3 mm
size
φ360mmx600mm(L) or φ390mmx600mm(L)
(optional)
Vacuum
<1 x 10-2 mbar
Small transition cabin
material
Stainless steel type 304 (1.4301),
thickness 2 mm
size
φ150mm x 330mm(L)
Vacuum
<1 x 10-2 mbar
Cleaning system
description
After setting the corresponding time and pressure, the system can
automatically perform gas replacement on the box.
Analyzer
Oxygen
analyzer
size
205 mm (L) x 80 mm (W) x 60 mm (H)
Measuring range
0-1000 ppm
Other oxygen analyzers
GE oxy.IQ™ Oxygen Transmitter
Moisture Analyzer
size
205 mm (L) x 80 mm (W) x 60 mm (H)
Measuring range
0-500 ppm
Other water analyzers
GE VeriDri™ Dew-Point Transmitter
Solvent purification system
description
Material: stainless steel 1.4301 (SUS type 304), thickness 3 mm
Internal size: 220mm(Φ) x 450mm(H)
High quality activated carbon
Optional equipment
refrigerator
Independent control system, integrated in the side panel of the
cabinet, temperature -35℃, volume 18L
or 32L optional
Main body 304 stainless steel sheet, 5 layers of variable compartments
R404 environmentally friendly refrigerant, imported with original
packaging
Heating chamber
Large transition configuration heating system, temperature is 200℃, temperature control is ±1℃
other instructions
certified product
ISO9001 certification, CE certification, UL certification
Warranty
One-year warranty, lifetime maintenance
Application note
For details, please refer to the dangerous, warning, and caution
clauses in the manual
Product Details