Build-in Purify System Vacuum Glove Box  For Lithium Battery R&D Research

Sales Build-in Purify System Vacuum Glove Box For Lithium Battery R&D Research

ACEY-GB1000 glove box is a high-performance, high-quality closed cycle working system that automatically absorbs water and oxygen molecules and purifies the working environment.

  • Product Origin : China
  • Order(Moq) : 1set
  • Payment : L/C,T/T,Western Union, Paypal
  • Warranty : One Year warranty with lifetime support
  • Item No. : ACEY-GB1000
  • Compliance : CE Certified
  • Brand : ACEY
  • Lead Time : 7days

Product Detail  

Build-in Purify System Vacuum Glove Box  For Lithium Battery R&D Research

Description

ACEY-GB1000 glove box is a high-performance, high-quality closed cycle working system that automatically absorbs water and oxygen molecules and purifies the working environment. It provides an inert atmosphere of 1ppm O2 and H2O that can meet your specific cleaning requirements. This system is an economical circulating purification system designed to meet customer research and development.

   The ACEY-GB1000 system includes a closed box, a transition chamber, a rotary vane vacuum pump and a circulating purification system integrated with a microcontroller operation panel. The inert gas purification system equipped with the standard Lab2000 system is equipped with a set of purification columns (fully automatic and renewable) to purify and maintain the atmosphere in the glove box.

Specification

Box body glove box

description

Material: stainless steel 1.4301 (SUS type 304), thickness 3 mm

Size: 1200mm(L) x 750mm(W) x 900mm(H)

volume

0.8 m³

Front window

Panel: 8 mm thick safety tempered glass or 10 mm thick polycarbonate (optional)

Size: 1123mm(L) x 839mm(H)

Glove mouth

Hard aluminum alloy material or polyoxymethylene material (optional)

220 mm diameter, O-ring seal

gloves

Material: Butyl rubber

Thickness: 0.4 mm or 0.8mm (optional)

filter

Outlet and inlet filters, filtration <0.3μm

illumination

LED lighting is located on the top of the front window

Leak rate

Leak detection is carried out in accordance with the oxygen method and pressure change method in ISO 10648-2: 1994 / EJ/T 1096-1999 "Sealed Chamber-Part 2: Tightness Classification and Related Inspection Methods". The final acceptance test is carried out in accordance with the standard of first-level tightness <0.05 vol%/h.

GP20 gas purification system

description

Automatic removal of H2O and O2

Single purification column system, automatic regeneration (optional GP200 double purification column)

Closed gas circulation pipeline

Use voltage

AC 230 V / 50-60 Hz, 10 A or AC 115 V / 50-60 Hz, 20 A (optional)

Working gas

Working gas: N2, Ar, He (purity 99.999%)

Regeneration gas: H2 accounts for 5%-10%, the rest is working gas (purity 99.999%)

Vacuum pump

Specifications: Rotary vane vacuum pump, equipped with oil mist filter, with gas ballast control

Flow rate: 12 m³/h (7 cfm), double substrate, vacuum degree <2 x 10-3 mbar or dry pump (optional)

Cyclic unit

Oil-free high-speed fan

Air volume: 80 m³/h

valve

KF40 High Vacuum Valve

Leak rate

Leak detection is carried out in accordance with the oxygen method and pressure change method in ISO 10648-2: 1994 / EJ/T 1096-1999 "Sealed Chamber-Part 2: Tightness Classification and Related Inspection Methods". The final acceptance test is carried out according to the standard of level 1 tightness <0.05 vol%/h.

Control cabinet size

600mm (L) x 800mm (D) x 870mm (H)

Transition cabin

Large transition cabin

material

Stainless steel type 304 (1.4301),

thickness 3 mm

size

φ360mmx600mm(L) or φ390mmx600mm(L) (optional)

Vacuum

<1 x 10-2 mbar

Small transition cabin

material

Stainless steel type 304 (1.4301),

thickness 2 mm

size

φ150mm x 330mm(L)

Vacuum

<1 x 10-2 mbar

Cleaning system

description

After setting the corresponding time and pressure, the system can automatically perform gas replacement on the box.

Analyzer

Oxygen

analyzer

size

205 mm (L) x 80 mm (W) x 60 mm (H)

Measuring range

0-1000 ppm

Other oxygen analyzers

GE oxy.IQ Oxygen Transmitter

Moisture Analyzer

size

205 mm (L) x 80 mm (W) x 60 mm (H)

Measuring range

0-500 ppm

Other water analyzers

GE VeriDri Dew-Point Transmitter

Solvent purification system

description

Material: stainless steel 1.4301 (SUS type 304), thickness 3 mm

Internal size: 220mm(Φ) x 450mm(H)

High quality activated carbon

Optional equipment

refrigerator

Independent control system, integrated in the side panel of the cabinet, temperature -35, volume 18L or 32L optional

Main body 304 stainless steel sheet, 5 layers of variable compartments

R404 environmentally friendly refrigerant, imported with original packaging

Heating chamber

Large transition configuration heating system, temperature is 200, temperature control is ±1

other instructions

certified product

ISO9001 certification, CE certification, UL certification

Warranty

One-year warranty, lifetime maintenance

Application note

For details, please refer to the dangerous, warning, and caution clauses in the manual

Product Details
Build-in Purify System Vacuum Glove Box For Lithium Battery R&D Research


Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
X

Home

Supplier

Leave a message

Leave a message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.