Anti bedsore decubitus alternating pressure Medical bubble air mattress for hospital bed
The alternating pressure mattress with pump model B01 series intent to prevent and assist pressure ulcer treatment ,and the intended users are who have had pressure sores and may get pressure sores. By comparison with equivalent equipment and risk management, it is determined that the product is valid and the risk is acceptable.
The alternating pressure mattress with pump model B01 series are Composed by an air pump and a air mattress and air pipes. The air pump is powered by an AC power supply and contains a software control board. The mattress is assembled from a plurality of air cells and connecting tubes. Connect the air pump to the mattress through the air pipe.
Treatment function
When patients lay on the alternating mattress then reduce pressure for the patients. Prevention and adjuvant treatment of pressure sores.
APM-B01 Bubble Air Mattress
|
|
FEATURES
|
SPECIFICATIONS
|
· For both hospital and home care use
|
· Size: 2000*900*70mm (L*W*H) |
· A-B lines alternating air bubbles give super bedsore treatment
|
· No.of bubbles: 130 air bubbles
|
· Medical grade PVC material from Taiwan Nanya company,
durable and high quality
|
· End flaps: 400mm
|
· Warranty:1 year
|
· PVC thickness: 0.3mm or 0.4mm option
|
· One time welded by 200KW power high frequency machine
|
· Repair kit and hose included
|
· Daily output 2000pcs bubble mattresses
|
· Weight capacity: 135KG
|
APP-TKS2012 Air Pump | |
FEATURES |
SPECIFICATIONS
|
· Durable ABS pump case
|
· Power: 110V/60Hz or 220V/50Hz
|
· Extremely low noise,silent during working |
· Air output: ≥6L/min
|
· Knob control panel,easy to operate
|
· Pressure range: 20-120mmHg
|
· Pressure adjustable
|
· Cycle time: 12mins
|
· Warranty:2 years
|
· Power consumption: 12VA
|
|
· Fuse: 0.5A
|
|
· Size: 240*110*100mm(L*W*H)
|
|
· Net Weight: 0.77KG
|
What are Pressure ulcers?
A pressure ulcer is localized injury to the skin and/or underlying tissue usually over a bony prominence, as a result of pressure, or pressure in combination with shear. A number of contributing or confounding factors are also associated with pressure ulcers; the significance of these factors is yet to be elucidated.
Intended purpose of the device
This product is intended to help and reduce the incidence of pressure ulcers while optimizing patient comfort. It also provides following purposes:
1. to help and reduce the incidence of pressure ulcers while optimizing patient comfort.
2. for long term home care of patients suffering from pressure ulcers.
3. for pain management as prescribed by a physician.
The product can only be operated by personnel who are qualified to perform general nursing procedures and have received adequate training in knowledge of prevention and treatment of pressure ulcer.
‐ Exact medical indications
Intended use for patients who are inconvenient to move after surgery, patients who are lying down for a long time, as well as patients with stage I and II of pressure ulcers, are not suitable for patients with more severe pressure ulcers.
‐ Patient populations
Patient population is elderly, child, adult. Especially elderly and malnourished patients.