INPUT PV (ONLY FOR HYBRID)
|
Max. Input Power [W]
|
3900
|
4680
|
5980
|
6500
|
7800
|
Max. Input Voltage [V]
|
600
|
Start-up Input Voltage [V]
|
75
|
Rated Input Voltage [V]
|
360
|
MPPT Operating Voltage Range [V]
|
80-550
|
Max. Input Current [A]
|
13.5/13.5
|
Max. Short-circuit Current [A]
|
15/15
|
No. of Independent MPP Trackers
|
2
|
2
|
2
|
2
|
2
|
No. of Strings per MPP Tracker
|
1
|
1
|
1
|
1
|
1
|
BATTERY CONNECTION
|
Battery Type
|
Lithium Battery (LFP)
|
Battery Voltage [V]
|
85-450
|
Max. Charge/Discharge Current [A]
|
40
|
Communication Interface
|
CAN(Communicate With Inverter), RS485 (Upgrade BMS)
|
AC INPUT AND OUTPUT (GRID)
|
Max. AC Input Power [VA]
|
7000
|
7680
|
9600
|
10000
|
12000
|
Max. AC Input Current (per phase) [A]
|
31.8
|
34.9
|
43.6
|
45.5
|
54.5
|
Rated Output Power [W]
|
3000
|
3680
|
4600
|
5000
|
6000
|
Max. Output Apparent Power [VA]
|
3300
|
4048
|
5060
|
5500
|
6600
|
Rated Output Current (per phase) [A]
|
13
|
16
|
20
|
21.7
|
26.1
|
Max. Output Current [A]
|
14.3
|
17.6
|
22
|
23.9
|
28.7
|
Rated Grid Voltage [V]
|
2220/230/240
|
Rated Grid Frequency [Hz]
|
50/60
|
Power Factor
|
1 ( Adjustable from 0.8 leading to 0.8 lagging )
|
THDi [%]
|
<3 @rated power
|
EPS OUTPUT (WITH BATTERY)
|
Max. Output Apparent Power [VA]
|
5000
|
5000
|
6000
|
6000
|
6000
|
Peak Output Apparent Power (60s) [VA]
|
6000
|
6000
|
7200
|
7200
|
7200
|
Max. Current (per phase) [A]
|
21.7
|
21.7
|
26.1
|
26.1
|
26.1
|
Rated Output Voltage [V]
|
2220/230/240
|
Rated Output Frequency [Hz]
|
50/60
|
Power Factor
|
1 ( Adjustable from 0.8 leading to 0.8 lagging )
|
THDv ( linear Load) [%]
|
<2 @rated power
|
Switch time [ms]
|
<20
|
EFFICIENCY
|
Euro Efficiency [%]
|
97
|
Max. Efficiency [%]
|
97.8
|
Max. Battery Charge Efficiency
|
98.5
|
(PV to BAT) (@full load) [%]
|
Max. Battery Discharge Efficiency
|
97
|
(BAT to AC) (@full load) [%]
|
PROTECTION
|
Insulation Monitoring
|
YES
|
Residual Current Monitoring
|
YES
|
DC Reverse Polarity Protection
|
YES
|
Anti-islanding Protection
|
YES
|
AC Short-circuit Protection
|
YES
|
AC Overcurrent/Overvoltage Protection
|
YES
|
DC Switch
|
YES
|
SPD
|
DC: Type II, /AC: Type III
|
GENERAL DATA
|
Dimensions (WxHxD) [mm]
|
430*410*178
|
Weight [kg]
|
23
|
Installation
|
Wall-Mounted
|
Topology
|
Transformerless
|
Cooling Method
|
Natural
|
Noise Emission [dB]
|
35
|
Max. Operating Altitude [m]
|
2000
|
Operating Temperature Range [°C ]
|
-25-60
|
Humidity ( No Condensation ) [%]
|
0-100
|
Protection Degree
|
IP65
|
Standby consumption[W]
|
<10
|
Monitoring Module
|
WiFi, LAN, 4G, GPRS (Optional)
|
Communication
|
2*RS485, DRM, Ripple Control, USB
|
Display
|
LCD, App, Website
|
STANDARD COMPLIANCE (MORE AVAILABLE UPON REQUEST)
|
Safety
|
EN 62109-1, EN 62109-2
|
EMC
|
EN 61000-6-2, EN 61000-6-3
|
Grid Regulation
|
EN50549-1, C10 / 11, VDE-AR-N 4105, G98, G99, CEI 0-21, NRS 097-2-1, AS / NZS 4777.2
|