1.Wide range of MPPT input voltage ranges;
2.Outdoor use, protection grade IP65, adapt to harsh application environments;
3.RS485 and GPRS communication functions, remote monitoring and start-stop management through mobile
INTRODUCTION
This product hybrid solar pump inverter is specially designed for small field irrigation,drinking water in small towns pump system,using hybrid design with solar and utility/DG Energy online complementation.
Features:
8.Fully automatic operation control, soft start and soft stop,one key to start.
Model | JNP550L-V5 | JNP750L-V5 | JNP1K1L-V5 | JNP1K5L-V5 | JNP2K2L-SE-V5 | JNP2K2L-V5 | JNP3KL-V5 | JNP3K7L-V5 | JNP4KL-V5 |
PV Input |
|
|
|
|
|
|
|
|
|
D.C. Max. Input Voltage | 450V | 450V | 450V | 450V | 450V | 480V | 480V | 480V | 480V |
Recommended MPPT Voltage | 80~400V | 105~400V | 130~400V | 150~400V | 150~400V | 200~450V | 200~450V | 200~450V | 200~450V |
D.C. Max. Input Current | 15A | 15A | 15A | 15A | 20A | 15A | 30A | 30A | 30A |
Max. MPPT Effiffifficiency | >99% | >99% | >99% | >99% | >99% | >99% | >99% | >99% | >99% |
Number of String | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
A.C. Input |
|
|
|
|
|
|
|
|
|
Voltage | 198~265Vac,1PH | 198~265Vac,1PH | 198~265Vac,1PH | 198~265Vac,1PH | 198~265Vac,1PH | 198~264Vac,1PH | 198~264Vac,1PH | 198~264Vac,1PH | 198~264Vac,1PH |
Frequency | 50Hz/60Hz(±3%) | 50Hz/60Hz(±3%) | 50Hz/60Hz(±3%) | 50Hz/60Hz(±3%) | 50Hz/60Hz(±3%) | 50Hz/60Hz(±3%) | 50Hz/60Hz(±3%) | 50Hz/60Hz(±3%) | 50Hz/60Hz(±3%) |
A.C. Output |
|
|
|
|
|
|
|
|
|
Max. Motor Output Power | 0.55kW | 0.75kW | 1.1kW | 1.5kW |
2.2kW(3PH)/
1.5kW(1PH)
|
2.2kW |
3kW(3PH)/
2.2kW(1PH)
|
3.7kW(3PH)/
2.2kW(1PH)
|
4kW(3PH)/
2.2kW(1PH)
|
Rated Output Voltage | 220/230Vac (1PH or 3PH) | 220/230Vac (1PH or 3PH) | 220/230Vac (1PH or 3PH) | 220/230Vac (1PH or 3PH) | 220/230Vac (1PH or 3PH) | 220/230Vac (1PH or 3PH) | 220/230Vac (1PH or 3PH) | 220/230Vac (1PH or 3PH) | 220/230Vac (1PH or 3PH) |
Output Frequency Range | 0~50/60Hz | 0~50/60Hz | 0~50/60Hz | 0~50/60Hz | 0~50/60Hz | 0~50/60Hz | 0~50/60Hz | 0~50/60Hz | 0~50/60Hz |
Max.Output Current | 5A | 6A | 9A | 11A | 13A | 15A |
|
|
|
System |
|
|
|
|
|
|
|
|
|
Protection Level | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 |
Operating Temperature | -25~60℃ | -25~60℃ | -25~60℃ | -25~60℃ | -25~60℃ | -25~60℃ | -25~60℃ | -25~60℃ | -25~60℃ |
Cooling Way | Nature cooling | Nature cooling | Nature cooling | Nature cooling | Nature cooling | Nature cooling | Nature cooling | Nature cooling | Nature cooling |
Display | RS485,GPRS/Bluetooth(without LCD) optional | RS485,GPRS/Bluetooth(without LCD) optional | RS485,GPRS/Bluetooth(without LCD) optional | RS485,GPRS/Bluetooth(without LCD) optional | RS485,GPRS/Bluetooth(without LCD) optional | RS485,GPRS/Bluetooth(without LCD) optional | RS485,GPRS/Bluetooth(without LCD) optional | RS485,GPRS/Bluetooth(without LCD) optional | RS485,GPRS/Bluetooth(without LCD) optional |
Altitude | 3000m, above3000m need derate operarting |
3000m, above3000m need derate operarting |
3000m, above3000m need derate operarting |
3000m, above3000m need derate operarting |
3000m, above3000m need derate operarting |
3000m, above3000m need derate operarting |
3000m, above3000m need derate operarting |
3000m, above3000m need derate operarting |
3000m, above3000m need derate operarting |
Noise Emission | <50dB | <50dB | <50dB | <50dB | <50dB | <50dB | <50dB | <50dB | <50dB |
Compliance | EN 50178; IEC/EN 62109-1;IEC61800 | EN 50178; IEC/EN 62109-1;IEC61800 | EN 50178; IEC/EN 62109-1;IEC61800 | EN 50178; IEC/EN 62109-1;IEC61800 | EN 50178; IEC/EN 62109-1;IEC61800 | EN 50178; IEC/EN 62109-1;IEC61800 | EN 50178; IEC/EN 62109-1;IEC61800 | EN 50178; IEC/EN 62109-1;IEC61800 | EN 50178; IEC/EN 62109-1;IEC61800 |
Dimension(W/H/D) | 265/330/150(mm) | 265/330/150(mm) | 265/330/150(mm) | 265/330/150(mm) | 265/330/150(mm) | 265/330/150(mm) | 265/330/150(mm) | 265/330/150(mm) | 265/330/150(mm) |
Weight | 6.5kg | 6.5kg | 6.5kg | 6.5kg | 6.5kg | 6.5kg | 6.5kg | 6.5kg | 6.5kg |