Sales Manager: Andrea
Email: Andrea@tmaxlaboratory.com
Wechat: 18250801164
1100C Used in Glove Box Two in One Furnace with Both Box-type muffle and Tube
KTL1100-S is a small mixed tube / box furnace. The size of the furnace is 100 × 100 × 100mm. As a simple box furnace, the sample can be heat-treated in an air environment. This equipment is equipped with quartz tube and stainless steel sealing flange, which can heat-treat samples under vacuum or atmosphere protection. The maximum temperature of the equipment can reach 1100 ℃, and the power is only 1.2KW. In addition, the device is small in size and can be put into a glove box for operation.
Main technical parameters
Model |
KTL1100-S |
Power |
1200W |
Chamber size(mm) |
100X100X100(LXWXH)1L |
Tube size |
OD50*180mm, 350ml |
Dimension |
500X250X410mm(LXWXH) |
Main feature |
Box-type tubular dual-use. Small size, light weight, low power, can be used for operation in glove box and fume hood. The highest temperature can reach 1100℃. Open the door on the side for easy operation.
Plug the furnace plug as box furnace Insert tube as tube furnace |
Supply voltage |
220V |
Phase |
single phase |
Heating element |
resistance wire |
Control mode |
30-step program temperature control
1. The temperature control of the 30-segment program can only be adjusted by PID. 2. With over-temperature protection Broken-couple protection When the over-temperature or even-coupled circuit is broken, the heating circuit of the electric furnace is automatically cut off. (When the temperature of the electric furnace exceeds 1120 degrees or the thermocouple burns out, the AC relay on the main circuit will be automatically disconnected, the main circuit is disconnected, the ON lamp on the panel is off, the OFF lamp is on, and the electric furnace is limited to protect). 3. With 485 communication interface (standard configuration when software is selected) 4. With power-off protection function, that is, when the furnace is started after power-off, the program will not start from the starting temperature, but will start to rise from the power off. 5. The instrument has the function of temperature self-tuning. |
control mode |
intelligent PID |
over-temperature protection |
Yes |
overcurrent protection |
Yes |
· Broken pair protection and display |
Yes |
· Furnace material |
1. High-quality high-purity alumina polycrystalline fiber curing furnace formed by vacuum suction filtration. 2. Formed using Japanese technology. 3. The spacing and pitch of the resistance wires in the furnace are all arranged according to the best thermal engineering technology in Japan, and the thermal field is simulated by the thermal engineering software. |
control accuracy |
±1℃ |
Max. temp |
1050℃ |
Rated temp |
1000℃ |
· Thermocouple Type |
K |
silicon controlled |
TRIAC |
surface temp |
≤45℃ |
Warranty |
One year warranty and lifetime technical support. Special note: Consumable parts such as heating elements, sample crucibles, etc. are not covered by the warranty. Damage caused by the use of corrosive gases is not covered by the warranty. |
Precautions |
1. For safety, please put the stove in a ventilated place. 2. In order to increase the service life of the furnace, we recommend that the heating rate should not exceed 10℃/ min. The cooling rate does not exceed 5 ° C / min. 3. The furnace has no vacuum tightness, and it is forbidden to pass toxic or explosive gas. 4. It is forbidden to put the materials directly on the brick at the bottom of the furnace. 5. When heating, the materials and crucible should not touch the heating element and thermocouple. 6. When not used for a long time, please use the oven again. |
1 Standard exported package: Internal anticollision protection, external export wooden box packaging.
2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.
3 Responsible for the damage during the shipping process, will change the damage part for you for free.